Session 2L
Novel Micro/Nano Sensors for Biology or Medicine
3:30 PM to 5:00 PM
- Presenters
-
- Aaron Matthew (Aaron) Bestick, Senior, Electrical Engineering NASA Space Grant Scholar, Washington Research Foundation Fellow
- Nathan Darrel Staley, Senior, Materials Science & Engineering
- Mentors
-
- Alexander Mamishev,
- Kishore Sundara-Rajan,
- Session
-
- 3:30 PM to 5:00 PM
Skin blisters and irritation at the interface between a prosthetic device and a patient’s residual limb are common problems for amputees. At present, few quantitative methods exist for the measurement and adjustment of the forces exerted at this interface. A need exists for sensing technology which can be used to measure these forces and facilitate precise adjustments of prosthetic geometry to increase wearer comfort. Our research objective was to produce a flexible, stretchable, capacitance-based shear and normal force sensing array, which could be integrated with moisture and temperature sensors into a “sensitive skin.” This sensing array could then be attached inside the prosthetic socket and used to monitor and reduce factors which result in sores and discomfort. A prototype force sensing array was constructed from individual rigid sensor cells connected by conductive fabric to create a stretchable, flexible sensor capable of measuring applied shear and pressure forces. Static load tests were then conducted in order to characterize the response of individual sensor channels to shear and pressure forces, as well as the crosstalk between channels. Additional tests were conducted to measure the accuracy and uniformity of individual cells in the array. Measurement drift over time was also characterized. The test results were used to calibrate the sensor to enable accurate force measurements. In addition, custom software was developed to collect, process, and display sensor data in real time. Subsequent work will include characterization of sensor response to dynamic loading, as well as development of a complete, integrated sensor package suitable for installation in prosthetics. In addition to biomedical uses, the sensor arrays have potential applications in a broad array of other fields, including medical and industrial robotics, where the sensors could be used to give autonomous machines a human-like sense of touch.
- Presenter
-
- Douglas Guy (Douglas) Cheung, Senior, Bioengineering
- Mentor
-
- Miqin Zhang,
- Session
-
- 3:30 PM to 5:00 PM
There has been an increasing interest on the design of surface functionalized magnetic nanoparticles for cancer diagnosis, prognosis, and treatment, due to their potential uses in non-invasive medical imaging, targeted drug delivery and gene therapy. We developed (poly(ethylene glycol)-grafted-chitosan)-coated iron oxide nanoparticles for their high biocompatibility and low toxicity compared with many traditional nanoparticles. This noval nanoparticle system uses iron oxide as the core for its superparamagnetic properties to enhance T2 contrast in magnetic resonance imaging. The core is then coated with a graft copolymer of chitosan and poly(ethylene glycol) (PEG). Chitosan is used to provide abundant active amine groups for further cojugation of biomolecules. PEG is used to increase the solubility of chitosan during synthesis, increase circulation time and reduce non-specific binding by its innate steric hinderance. A protocol has been developed to optimize the conjugation of PEG to chitosan and use the resulted co-polymer as the coating to stabilize the nanoparticles and prevent aggregation. The nanoparticles are characterized by an improved UV spectroscopic assay to determine the percentage of PEG conjugated to chitosan, a ferrozine assay to measure iron concentration, and a fluorescamine assay to quantify the average number of PEG-grafted-chitosan molecules per nanoparticles. Nanoparticles are delivered with a small (~40nm) monodispersed hydrodynamic size and high stability in different biological buffers, including phosphate buffered saline and Dulbecco's modified Eagle's medium with 10% fetal bovine serum.
- Presenter
-
- Jordan T (Jordan) Crawford, Senior, Chemical Engineering
- Mentors
-
- Daniel Schwartz,
- Valerie Lieu,
- Session
-
- 3:30 PM to 5:00 PM
Cells are normally characterized based on the behavior of their populations, rather than the behaviors of single cells. However, within a population of cells, individuals often behave differently from the average, even when all the cells are genetically identical. We present a microeddy device with the ability to trap, hold, and release arrays of single cells, allowing real-time analysis of their phenotypic traits. The device consists of a channel with posts arranged in arrays. Microeddies form in an oscillating flow where the streamlines bend near the posts. These microeddies can trap different size and density objects with the advantage over other cell isolation techniques in that the cells are in contact with nothing but their natural media. As the strength and size of the traps can be controlled by tuning the oscillation amplitude and frequency, both motile and non-motile cells can be trapped at audible frequencies (4kHz-20kHz). We use a model system comprised of polystyrene microspheres to study the statistics of trap filling in the device. At low particle concentration ranges, the numbers of particles trapped follows a Poisson distribution. Thus, we show that cell densities can be statistically determined in the microeddy trapping device by simply taking a snapshot image and comparing the number of trapped cells to the Poisson distribution. We demonstrate the use of fluorescent dyes and auto-fluorescence from algae as a way to observe lipid content of cells in the array. This device provides an innovative platform to analyze stationary single cells and determine cell concentration.
- Presenter
-
- Jun Beom (James) Park, Senior, Bioengineering Mary Gates Scholar, Washington Research Foundation Fellow
- Mentors
-
- Mehmet Sarikaya,
- Yuhei Hayamizu,
- Christopher So,
- Session
-
- 3:30 PM to 5:00 PM
Recent research conducted in the Sarikaya lab has revealed that Graphite-binding peptide (GrBP5) can self-assemble onto graphite substrates and form long-range ordered structures. The structure of the peptide nanowires have been found to correspond to the hexagonal symmetry of the underlying graphite surface. In this research, streptavidin-coated quantum dots (SA-QD) are immobilized on graphite surface via biotinylated-GrBP5 (Bio-GrBP5). Upon formation of peptide nanowires via Bio-GrBP5, SA-QDs were immobilized onto graphite surface only on the regions with peptide wires while maintaining an even spacing between each SA-QD. Additionally, it was found that the long-range ordered structure of Bio-GrBP5 can be thermally controlled by controlling its diffusion. Upon initial binding of Bio-GrBP5, the peptides are immobilized on graphite surface in an amorphous peptide cluster. Following the immobilization, the peptides are allowed to diffuse as the substrates are kept in a humid, high-temperature environment where they re-arrange to form peptide nanowires. By using atomic force microscopy and fluorescence microscopy, ordered peptide morphologies, immobilization of SA-QD and phase transformation of immobilized peptides at various conditions are verified. This research presents a simple but highly controllable platform for nano-scale immobilization of biomolecules via molecular recognition and self-assembly for applications in bio-sensors and electronics.
The University of Washington is committed to providing access and accommodation in its services, programs, and activities. To make a request connected to a disability or health condition contact the Office of Undergraduate Research at undergradresearch@uw.edu or the Disability Services Office at least ten days in advance.